Serial number |
project |
General parameters |
1 |
Number of series |
16S |
2 |
Rated voltage |
51.2V or 48V |
3 |
End of discharge voltage |
43.2V or |
4 |
Charging voltage |
Recommend 56.4V (56V – 58.4V) |
5 |
Internal resistance (battery pack) |
≤100mΩ |
6 |
Self-discharge rate |
≤2%/month |
7 |
range of working temperature |
0~65℃ charge |
8 |
Storage temperature range |
-40~70℃ |
9 |
Positive and negative lead way |
Terminal 4P*1 Fence terminal*1 |
10 |
Display screen |
LED display, four physical buttons |
11 |
Protective function |
Overcharge, over discharge, short circuit, overload, over temperature, etc. |
12 |
Shipment product charge |
50% power when delivery |
13 |
Packing material |
Carton or Wooden box |
S/N |
function name |
Function setting |
Cell voltage alarm |
Settings Value |
Reference setting range |
1 |
Monomer over-voltage protection |
Turn on |
Over-voltage protection voltage |
3750mV |
3000~6000mV |
2 |
Cell under-voltage protection |
Turn on |
Under-voltage protection voltage |
2700mV |
100~3200mV |
3 |
Battery over-voltage protection |
Turn on |
Over-voltage protection voltage |
57.6V |
40.0V~60.0V |
4 |
Battery under-voltage protection |
Turn on |
Under-voltage protection voltage |
43.2V |
30.0V~60.0V |
5 |
Cell high temperature protection |
Turn on |
Cell high temperature protection |
65℃ |
30℃~90℃ |
6 |
Charging low temperature protection |
Turn on |
Charging low temperature protection |
0℃ |
-5~5℃ |
7 |
Discharge low temperature protection |
Turn on |
Discharge low temperature protection |
-20℃ |
-40~-10℃ |
8 |
Overcurrent protection |
Turn on |
Overcurrent protection |
105A |
0A~110A |
Performance Curves